Intake Vents and Spray Foam Insulation

SmartVent eave installation

Intake Vents

are an integral part of your roof and required to maintain a source of airflow for proper ventilation. Air comes in through the soffits or vent like DCI Products’ SmartVent and then travels up between the rafters and exhausts through the ridge (see SmartRidge II). Insulation is also an important factor in the health of the home, but also causes the greatest difficulties when blocking the intake area.

Great care needs to be shown when having insulation installed in the attic space to make sure your intake does not get blocked. Installing insulation baffles such as SmartBaffle, can be installed with a wind blocker. This type of full rafter width baffle guarantees that your intake area will remain clear of loose fill insulation and also allow the adherence of spray foam insulation.

Various types of attic intake vents.

  • Perforated soffit vents are installed on under the eave, made of a perforated plastic or metal.
  • Fascia vents are typically used when there is no overhang at the eave and also used when the roof pitch is less than a 4:12 pitch (see: What does roof pitch mean) .
  • Over Eave vents are installed on the roof decking and hidden under the shingles or metal roof. These vents require an opening to be cut on the roof decking to allow air to flow in. Over eave vents are used when there are no soffits, exposed rafter tails, insulation blocking the soffit or internal blocking that will not otherwise allow air to enter through the soffit or fascia. (see: SmartVent attic intake)
Soffit vent

Perforated soffits are installed beneath the eave.

FasciaVent for any roof without soffits

FasciaVent for any roof without soffits

SmartVent for intake and exhaust attic ventilation.

SmartVent is installed on the roof deck.

Various types of attic intake vents.

Perforated soffit vents are installed on under the eave, made of a perforated plastic or metal.

Soffit vent

Perforated soffits are installed beneath the eave.

Fascia vents are typically used when there is no overhang at the eave and also used when the roof pitch is less than a 4:12 pitch (see: What does roof pitch mean) .

FasciaVent for any roof without soffits

FasciaVent for any roof without soffits

Over Eave vents are installed on the roof decking and hidden under the shingles or metal roof. These vents require an opening to be cut on the roof decking to allow air to flow in. Over eave vents are used when there are no soffits, exposed rafter tails, insulation blocking the soffit or internal blocking that will not otherwise allow air to enter through the soffit or fascia. (see: SmartVent attic intake)

SmartVent for intake and exhaust attic ventilation.

SmartVent is installed on the roof deck.

SmartBaffles for use with all intake venting

SmartBaffle is available in 16” and 24” On Center rafter.These stock sizes will fit snuggly in common 14.5″ and 22.5″ rafter bays. These insulation baffles are strong, durable, easy to work with and can be used in new construction or retrofit during renovations.

Click here to learn more about SmartBaffles>>

Intake Vents and Spray Foam Insulation

Insulation baffles

help maintain an air gap between the insulation and the roof deck; they also help direct air movement and prevent wind from blowing the insulation out of place.

If the attic space is going to be conditioned, either for living or mechanical purposes, or if a home design calls for a vaulted ceiling, provision R806.3 in the International Residential Code calls for the roof deck above the space to be vented continuously from the eave to the ridge. This is easy to accomplish in simply constructed roofs and difficult, if not impossible, to accomplish in roofs that have hips, valleys, dormers, or skylights that interrupt the rafter bays.

“The success … hinges on the ceiling of the top level of the house being absolutely airtight before any insulation is installed.”

Spray foam insulation

is a great product for maintaining a consistant temperature within a structure. Insulation baffles compliment spray foam by providing seamless airflow under the roof deck keeping the airflow from eave to ridge. Baffles should be used prior to an installation of spray foam to maintain the shingle warranty and most importantly to prevent any moisture build up from under the roof deck that could cause mold or rot.

Every rafter bay should be vented for proper airflow for the entire attic space for better life of a roof.

Every rafter bay should be vented for proper airflow for the entire attic space.

SmartBaffles provide a full 2 inch pathway for proper ventilation.

SmartBaffles provide a full 2 inch pathway for proper ventilation.

Intake Vents and Spray Foam Insulation

How to properly ventilate your attic when using spray foam.

Intake Vents and Spray Foam Insulation

The Need for Ventilation as Described in ICC Building Codes

In the 2024 ICC Building Codes (IBC), attic ventilation is addressed as, “An airspace of not less than 1 inch (25 mm) shall be provided between the insulation and the roof sheathing.” SmartBaffles exceed that requirement by providing 2 inches of airspace insuring a clear and up to code airflow.

Follow this link to read the entire ventilation code

Are You Risking Your Shingle Warranty?

Before you contract to have spray foam insulation installed in an attic space you may want to install SmartBaffles prior spray foam to ensure the shingle warranty is not going to be impacted. Most manufacturers will require ventilation that would meet or exceed building codes.

From Owens Corning Technical Bulletin (TB-10023711):

“Ventilation systems should provide balanced intake and exhaust with adequate net free vent area (NFVA) that meets or exceeds code requirements. Not venting attics may introduce moisture related problems in the attic, and moisture management issues can lead to mold and damage to the internal structure of a home. Further, installing a spray foam system can make it more difficult to detect roof leaks.”

Intake Vents and Spray Foam Insulation

From GAF Technical Advisory Bulletin (TAB-R-135):

Will Sprayed-In-Place Foam Insulation Void My Warranty?
No, the GAF Shingle Limited Warranty against manufacturing defects will remain in effect.
However, any damage to the shingles attributable to using sprayed-in-place insulation
directly applied to the roof deck or lack of ventilation is excluded from GAF’s responsibility
under the terms of our Limited Warranty.

Intake Vents and Spray Foam Insulation

From Atlas Roofing (atlasroofing.com)

Correct Installation of Spray Foam to Maintain the Warranty

Atlas Roofing does approve and warranty the use of Atlas shingles with spray foam in certain situations:

The system must maintain a free flow of air on the underside of the roof deck from soffit to ridge.

Baffles should be installed between the rafters before spray foam insulation.

Intake Vents and Spray Foam Insulation
Intake Vents and Spray Foam Insulation

Fine Hombuilding: Joseph Lstiburek

From: A Crash Course in Roof Venting

So much information has been devoted to the subject of roof venting that it’s easy to become confused and to lose focus. So I’ll start by saying something that might sound controversial, but really isn’t: A vented attic, where insulation is placed on an air-sealed attic floor, is one of the most underappreciated building assemblies that we have in the history of building science. It’s hard to screw up this approach. A vented attic works in hot climates, mixed climates, and cold climates. It works in the Arctic and in the Amazon. It works absolutely everywhere—when executed properly. – Full article